BD FACSCelesta Analysis Cytometer with High Throughput Sampler
Please acknowledge the FCSF (Flow Cytometry Shared Facility) in publications and talks using RRID: SCR_019309 and Instrumentation Grant Number S10 OD 021601. It is a requirement of funding agencies and CRUCIAL FOR FUTURE FUNDING.
We thank the Flow Cytometry Shared Facility in JSCBB (RRID: SCR_019309 and Instrumentation Grant Number S10 OD 021601) in the Department of Biochemistry, °Ç¸ç³Ô¹Ï for the use of [insert flow cytometry instrument/s used for experiment].
An RRID is a unique reference tag associated with a specific research resource. Robust metrics tracked by an RRID in publications enable the metrics needed for requesting new instrument funding and promotes meticulous rigor and reproducibility of research results.
Three laser system: 405 nm, 488 nm and 561 nmÌý
High Throughput Sampler (HTS) for rapid sample processing of various size plates and well shapesÌý
12 fluorescence detection channelsÌý
BD FACSDiva SoftwareÌý
BD FACSCelesta Configuration and Filters
The high throughout sampler (HTS) attachment for the BD FACSCelesta allows users to automate sample acquisition in 96 and 384 well plates. Flat, V, and U-bottom 96 well plates are compatible with the HTS while only flat-bottom 384 well plates work. The HTS can process a 96 well plate in approximately 15 minutes in high-throughput mode and about 45 minutes in standard mode.ÌýÌý
Users are able to adjust voltages while in plate mode. In addition to plate acquisition specific parameters such as sample flow rate, sample volume, mixing volume, mixing speed, number of mixes, and wash volume.ÌýÌý
The cytometer is in tube mode by default. Using the HTS is not included in the standard flow cytometry training and requires an additional training session before access is granted. Please contact the facility staff to schedule a training session if your experiments' sample size is appropriate for the HTS (20+ samples).Ìý
Is the Celesta the right instrument for you?Ìý
Our staff is here to assist you. Please reach out!
PLANNING YOUR EXPERIMENTÌý
Planning your experiment begins with understanding the excitation and emission of all your fluorophores, choosing the best fluorophore combinations and having proper controls. Please visit our suggested spectra visualization websites under our Protocols and Resources menu. There are also helpful links to protocols and educational resources.
Sample PreparationÌý
The outcome of a cell or particle analysis will only be as good as the sample preparation.Ìý It is crucial to minimize clumps in the sample, usually caused by inadequate dissociation and/or cell death and subsequent release of DNA from dead cells. We strongly encourage all samples be filtered through a 50 uM filter (available for checkout near the Flow Cytometry Shared Facility, room C355).Ìý
The BDFACS Celesta requires specific 5 mL polystyrene round-bottom tubes.Ìý These are available for checkout, or a lab wishes to purchase their own supply, the following catalog numbers may be used:Ìý
TUBES, 5 mL Polypropylene, round-bottom,Ìý 12 X 75 mm p/n 352063Ìý | 500/cs; 25/packÌý 1000/cs; 125/bgÌý 25/pkÌý | 14-959-11AÌý 14-959-2AÌý 60819-728Ìý |
The minimum volume that can be run is ~300 uL at a final cell concentration of 1 x 106 cells per ml. However, we strongly recommend having a minimum volume of 500 uL.
Ìý
- Unstained cellsÌý
- Positive Control: Target protein is expressed in abundance. This helps set voltages and can be a check to verify a staining protocol worked, if performed.Ìý
- Secondary antibody alone (no primary antibody): This verifies that your observed signal is not from non-specific binding of the secondary antibody.Ìý
- Isotype Control: This is a sample incubated with an antibody from the same isotype (for example, IgG1, IgG2A, IgM) and at the same concentration as your primary antibody but does not react with your target antigen This control checks that non-specific interactions of the primary antibody do not cause the observed staining and is very important when analyzing rare populations.Ìý
- Single stained controlsÌý
Fluorescence Minus One (FMO) controls are cells (same cell type as your sample) stained with all the fluorochromes minus one fluorochrome. These controls allow one to take into account any spread or spillover of fluorochromes into the detector channel of your missing fluorophore, allowing correct placement of gates.Ìý
FMO controls are critical when one has dimly expressed antigens or a continuous distribution of staining.Ìý
Whatever method is chosen (and they both have pros and cons), it is always a good idea to perform the fixation process using cold solutions and vortexing cells gently! It is also imperative to do things in the right order for optimal results.ÌýÌý
All fixatives can change the light-scattering properties of cells and cause increased background autofluorescence, a real problem in analyzing dim or low abundant populations of interest.Ìý
Alcohol (ethanol or methanol) fixationÌýÌý
Good news is that cells fixed in ethanol are stable at 4°C or -20°C for months!Ìý
Alcohols are a precipitating fixative that coagulates proteins and dissolves lipids in the cell and nuclear membranes, creating holes.Ìý This is a great method when doing DNA analysis as precipitation of protein around the DNA provides even access to the dye, leading to a better coefficient of variation (CV; low spread of data).Ìý
The bad news is that coagulation of proteins can lead to conformational changes of your target protein. This may prevent the recognition by your antibody to its specific epitope.
Methanol fixation protocol:ÌýÌý Ìý
Ìý
Meticulously following a standardized fixation protocol will lead to the most consistent results. This includes aldehyde concentration and purity, buffer type, total time in the fixative, and post-fixation storage.Ìý
Formaldehyde fixation involves the formation of cross-links between proteins and is a widely used method due to the preservation of cellular structure across a wide range of cell types. It does not appear to result in significant structural changes to proteins, unlike alcohol-based fixation.Ìý
A downside is that formaldehyde fixed cells are only stable for 1-2 weeks.Ìý
For fixation purposes, users have reported optimal results using fresh formaldehyde diluted with phosphate-buffered saline (PBS) to a concentration of anywhere between 0.5% and 4%.Ìý
A fixation protocol combining both methods that may work for youÌý
Contributed by , University of Birmingham, United KingdomÌý
Alternative fixation procedure for FACS fixation, using formaldehyde fixatice.Ìý
- Fix cells with 2% fresh formaldehyde in PBS for 5-15 minutes.Ìý Gentle rotation may help improve fixation.ÌýÌý
- Wash cells 2-3 times with PBS to remove all the formaldehydeÌý
- Resuspend cells in 300ul of PBSÌý
- Add 700ul of 100% -20°C EtOH to permeabilize the cells - they can now optionally be stored for weeks at –20°C.Ìý
Due to the high level of autofluorescence and nonspecific antibody binding seen with dead cells, eliminating them from analysis becomes important to prevent the inclusion of false positives, and having a loss of resolution.Ìý Detection of weakly positive and rare populations becomes more difficult.Ìý
Because dead/dying cells have compromised membranes, the following two dyes can pass through the membrane and stain the nucleus.
- Propidium Iodide (PI)Ìý
PI is excited by 488 nm and 561 nm lasers. In addition to its broad excitation range and emits maximally at 620 nm.ÌýÌý
ÌýGeneral Protocol (Molecular Probes):ÌýÌý
If fixing cells, use the protocol that works best with your cells.ÌýÌý
- To 200,000 to one million cells that have been centrifuged and resuspended in one mL of room temperature PBS, add 4 mL of –20o C absolute ethanol while vortexing. Leave in ethanol at –20o C for 5 to 15 minutes. Pellet cells by centrifugation, discard ethanol and add 5 mL room temperature PBS. Wait 15 minutes to allow cells to rehydrate.Ìý
- Make a 3 uM solution of PI by diluting a stock solution (1.5 mM; 1 mg/mL) 1:500 in staining buffer (100 mM Tris, pH 7.4, 4, 150 mM NaCl, 1 mM CaCl2 , 0.5 mM MgCl2 , 0.1% M Tris, Nonidet® P-40).Ìý
- 1 mL volume will be required for each cell sample.Ìý
- Hoechst 33258Ìý
Hoechst is best excited by the 355 nm UV laser but will also excite with a 405 nm violet laser for live/dead discrimination. It mainly emits in the region around 460 nm. Note that 405 nm excitation does not work well for cell cycle analysisÌý
Ìý